Measurement error of self-paced exercise performance in athletic women is not affected by ovulatory status or ambient environment

Loading...
Thumbnail Image
Date
2021-11
Open Access Location
Journal Title
Journal ISSN
Volume Title
Publisher
American Physiological Society
Rights
CC BY 4.0
Abstract
Measurement error(s) of exercise tests for women are severely lacking in the literature. The purpose of this investigation was to 1) determine whether ovulatory status or ambient environment were moderating variables when completing a 30-min self-paced work trial and 2) provide test-retest norms specific to athletic women. A retrospective analysis of three heat stress studies was completed using 33 female participants (31 ± 9 yr, 54 ± 10 mL·min−1·kg−1) that yielded 130 separate trials. Participants were classified as ovulatory (n = 19), anovulatory (n = 4), and oral contraceptive pill users (n = 10). Participants completed trials ∼2 wk apart in their (quasi-) early follicular and midluteal phases in two of moderate (1.3 ± 0.1 kPa, 20.5 ± 0.5°C, 18 trials), warm-dry (2.2 ± 0.2 kPa, 34.1 ± 0.2°C, 46 trials), or warm-humid (3.4 ± 0.1 kPa, 30.2 ± 1.1°C, 66 trials) environments. We quantified reliability using limits of agreement, intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV). Test-retest reliability was high, clinically valid (ICC = 0.90, P < 0.01), and acceptable with a mean CV of 4.7%, SEM of 3.8 kJ (2.1 W), and reliable bias of −2.1 kJ (−1.2 W). The various ovulatory status and contrasting ambient conditions had no appreciable effect on reliability. These results indicate that athletic women can perform 30-min self-paced work trials ∼2 wk apart with an acceptable and low variability irrespective of their hormonal status or heat-stressful environments. NEW & NOTEWORTHY This study highlights that aerobically trained women perform 30-min self-paced work trials ∼2 wk apart with acceptably low variability and their hormonal/ovulatory status and the introduction of greater ambient heat and humidity do not moderate this measurement error.
Description
Copyright © 2021 The Authors
Keywords
females, heat stress, hormones, performance, reliability, Body Temperature Regulation, Female, Hot Temperature, Humans, Reproducibility of Results, Retrospective Studies, Sports
Citation
Zheng H, Badenhorst CE, Lei T-H, Che Muhamed AM, Liao Y-H, Amano T, Fujii N, Nishiyasu T, Kondo N, Mündel T. (2021). Measurement error of self-paced exercise performance in athletic women is not affected by ovulatory status or ambient environment.. J Appl Physiol (1985). 131. 5. (pp. 1496-1504).
Collections